BLUGUARD SmartBus P900-V16N Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
version 1.1
29
SmartBus P900
-
V16
N
NN
N
USER MANUAL
Users are advised to test the system as frequent as possible. System must be tested at least once
every 3 months. If the system is not functioning accordingly, please contact your system installer
for technical assistance.
[MODE] + [1] + [#]
1. Walk Test allows on-site testing of each zone of the system.
2. During walk test mode, the P1, P2 and SERVICE indicators will slow flash.
3. Siren will trigger for 2 seconds and keypad buzzer will sound briefly if any zone is violated
during walk test mode.
4. If siren and keypad do not sound when zone is violated, consult your system installer.
5. To exit Walk Test, simply press [#] key.
[MODE] + [2] + [#]
1. CMS Test allows on-site testing of CMS Reporting.
2. A CMS testing code will be sent to the central monitoring station.
3. Wait for 2 minutes, if CMS reporting fails then a new trouble condition will be registered.
4. Press and hold down [7] key for 2 seconds to view trouble condition and consult your
system installer.
[MODE] + [3] + [#]
1. Siren Test allows on-site testing of siren functionality.
2. Siren will sound for 3 seconds.
3. If siren does not sound, consult your system installer.
[MODE] + [4] + [#]
SIREN TEST
CMS TEST (Manual Test)
WALK TEST
TESTING THE SYSTEM
STROBE LIGHT TEST
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31