[0] + [1 or 2] + [#]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for long away occasion (holiday).
2. In this mode, the system will be AWAY armed. Home Automation points will be random
ON/OFF every hour to simulate occupancy from 7pm to 1am.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. Enter and hold down [0] key for 2 seconds.
5. Zone indicator [1] and [2] will flash.
6. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
7. The P1 indicator will illuminate of Partition 1 is armed.
8. The P2 indicator will illuminate of Partition 2 is armed.
9. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
10. Leave the premises only via the EXIT/ENTRY zone.
11. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
12. After disarming, Home Automation random ON/OFF function will be deactivated and the
system will resume to normal Home Automation ON/OFF timers setting.
[USER CODE] + [#]
1. To disarm the system, enter a valid 4-digit [USER CODE] followed by [#] key before expiry
of the entry delay time.
2. Enter the premises through a designated ENTRY/EXIT zone; entering via other zones will
trigger an alarm instantly.
3. The ENTRY delay begins once the ENTRY zone is violated.
4. The keypad audible indicator will sound for the duration of the ENTRY delay to indicate that
a valid user code is required.
5. Zone indicator [1] and [2] will flash.
6. Enter key [1] to disarm Partition 1 or enter key [2] to disarm Partition 2 followed by [#] key.
7. The P1 indicator will turn off if Partition 1 is disarmed.
8. The P2 indicator will turn off if Partition 2 is disarmed.
9. If the P1 or P2 indicators remain illuminated, an error has been made while entering the
user code, press [∗
∗∗
∗] key and re-enter the user code.
10. Once the system is disarmed, the P1 indicator will extinguish and the keypad audible
indicator will stop.
11. If no valid user code has been entered by the end of the ENTRY delay period, an ALARM
condition will be registered and stored into the system MEMORY.
Comentarios a estos manuales