version 1.1
20
1. This arming mode is ideal for DAY time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, DAY STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [2] for 2 seconds.
6. Zone indicator [1] and [2] will flash.
7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate of Partition 1 is armed.
9. The P2 indicator will illuminate of Partition 2 is armed.
10. Any DAY STAY zones will be automatically bypassed (shown by flashing zone indicators).
11. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[3] + [1 or 2] + [#]
(Press and hold down for 2 seconds)
1. This arming mode is ideal for NIGHT time arming with user still remains in the protected
premises.
2. In this mode, system will be armed instantly with certain preprogrammed, NIGHT STAY
zones bypassed automatically.
3. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
4. DO NOT open the ENTRY/EXIT zone.
5. Enter and hold down key [3] for 2 seconds.
6. Zone indicator [1] and [2] will flash.
7. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
8. The P1 indicator will illuminate of Partition 1 is armed.
9. The P2 indicator will illuminate of Partition 2 is armed.
10. Any NIGHT STAY zones will be automatically bypassed (shown by flashing zone
indicators).
11. There is no ENTRY delay in this arming mode. Any violation on the active zones will trigger
the system instantly.
[4] + [1 or 2] + [#]
(Press and hold down for 2 seconds)
1. In this mode, the system will be armed with EXIT delay time which allows certain violated
zones to be bypassed temporary. When the violated zones resume, the zone will be
protected again.
2. Enter and hold down key [4] for 2 seconds.
3. Zone indicator [1] and [2] will flash.
4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. Keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
8. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.